DIGITAL KEYPAD (STANDALONE) - The Deca digital entry system comes in two versions, common code (2 codes) or multiple code (100 codes). The common code unit should be used in situations where all authorized personnel use the same entry code either timed or 24 hours. The multiple code unit is to be used where authorized personnel are to be issued with individual codes that can be deleted when no longer required without affecting other people's codes, again these can be timed or 24 hour. Keypads are vandal resistant as slim fitting 2 x 6 format (surface) or standard fitting 3 x 4 format (surface and flush). Up to two Deca Digital Controllers can be connected to a Deca Printer Interface to provide a printed record of events. |
![]() |
MAG SWIPE CARD (STANDALONE) -
The Deca Mag
Swipe card access system comes in eleven versions, card only or
card/PIN for 20 users, 500 users, 1500 users, 5000 users, 10000
users or 32000 users. The card only versions allow full feature
programming of all cards and can be used for internal or external
doors. The card/PIN version (up to10000 users) allows full feature
programming but has the additional security of a personal ID number
per card, this extra security allows the system to be used for
internal or external doors in higher security areas. Card readers
can be standard or waterproof swipe both surface mounted. Up to two
Deca card controllers can be connected to a Deca Printer Interface
to provide a record of events.
|
![]() |
PROXIMITY TAG (STANDALONE) -
The Deca
Proximity Tag access system also comes in eleven versions, tag only
or tag/PIN for 20 users, 500 users, 1500 users, 5000 users, 10000
users or 32000 users. All versions allow full programming of tags
with similar applications to the Deca swipe systems. The proximity
tag comes in three versions, credit card sized, half shell and ISO
card or a keyfob. All tags have a read range of around 50mm and
provide real, non contact, vandal resistant, low maintenance access
control. Standard proximity readers can be surface or flush mounted
with special readers and tags giving a read range of up to 7000mm.
Up to two Deca card controllers can be connected to a Deca Printer
Interface to record events.
|
![]() |
RDF - RANDOM DATA FORMAT (S/A) -
The Deca Random
Data Format (RDF) controller has all of the features of a standard
Deca controller but can use the data from existing cards (ie) other
access cards. The unit comes in six versions up to 20 up to 500 and
up to 900 users for card or card/PIN. This versatile controller uses
a built-in training mode to set up the data length for error
detection when loading cards. The RDF controller can accept data
from a variety of devices, (ie) Weigand output swipe readers (Sensor
or Dudoco), Weigand output Proximity or Mag Swipe readers (up to 44
bit), "Mifare" Proximity readers (detecting the unique "Mifare" card
number) & standard ISO track 2 or 3 Mag stripe output proximity or
mag swipe readers.
|
![]() |
CENTRAL CONTROL (PC BASED) - The Deca Central Control system allows Deca door controllers to be linked to a central computer via Local Area Controllers. This provides central programming for all cards/tags or codes with time zoning, auto event timing and an audit trail for all events. The standard system allows up to 80 doors/readers and the software can be set as either, demo, code or card based. The code based setting allows 100 users, each with a 4 digit code. The card based setting allows cards/tags for up to 500, 1500 or 10,000 users, with either card only or card/PIN access. The system can be interfaced with a fire alarm panel to create fire muster reports and is self monitoring for equipment failures and cable faults. |
![]() |
CENTRAL CONTROL (PC NETWORK) - One of the latest features to be added to the Deca Central Control system is the addition of networking modules (Deca-Net). These software modules enable the Central Control PC facility to be extended, allowing multiple operator positions across a local area network (LAN), with file interlocking between operators. Central Control systems can also be linked across multiple remote sites and/or remote buildings on a single site, via private wire, dial-up or radio modems. As with a single PC the multiple operators can be given either full access, view only or no access to menu options under password control. All standard Central Control features apply including time and attendance file generation. |
![]() |
SITE SUPERVISOR (PC BASED) - The Deca Site Supervisor system has been designed as a portable health and safety, fire muster and time and attendance logging system. Primarily used on construction sites to generate "presence on site" reports and fire muster listings in the event of an emergency. The system also produces time & attendance report files in a text format that can be analyzed in any word processor or spreadsheet. The card reader technology can be either mag swipe or proximity and the system comes in three versions up to 500 users, up to 1500 users or up to 10000 users. Cards can be our highly durable polyester swipe cards or proximity tags (card or keyfob) with on site ID easily produced for either technology. |
![]() |
PRINTER INTERFACE (STANDALONE) - The Deca Printer Interface is an intelligent interface unit that will connect any two Deca Standalone controllers, either digital, mag swipe or proximity to an Industry Standard parallel printer. This will allow all door transactions to be recorded, showing the day, date and time of personnel entries, alarms and system changes. If the printer is taken off line or switched off the Printer Interface will give an audio/visual alarm and store the last 100 entries in a rollover log to be printed out on reconnection. The Deca printer interface units can be connected together via industry standard, printer sharers allowing for more than two doors to be recorded, each with their own door ID numbers. |